Home  /  Products  /  Cooling Towers  /  LKH Series  /  Stainless Steel Closed Cooling Tower
LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower
  • LKM Series Counter Flow Closed Cooling Tower

LKM Series Counter Flow Closed Cooling Tower

LKM Series Counter Flow Closed Cooling Tower

Share
  • Features
  • Parameters
  • Dimension&Pipe Spec
  • Level of Noise

1.Control energy more accurate

As designed without fill,more quantity of pipe,could use double speed motor,that could provide more accurate energy control.The fan choose low speed operation when the load is reduced or wet bulb temperature is low,can produce 60% load capacity equivalent of full speed,and just need 15% energy of full speed.Low speed can significantly reduce noise of tower while saving energy. When the outside temperature is lower,spray water system can be turned off to achieve dry running,thus avoiding low temperature freezing of spray water.

2.Compact structure,Cover small area

The product assembly traditional condenser ,cooling tower,circuit pump,pool and connecting pipe in whole one,operate normally without another equipment.Cover small area,low investment cost.

3.Suitable for low temperature or small temperature difference in cooling fluid.

4.High-efficiency dehydrator

High-efficiency dehydrator is the standard part for closed circuit cooling tower,it makes the circuit rate of water reach 99.999%,so the cooling tower can be installed in the area sensitive to water mist.The material of dehydrator is PVC with corrosion resistance,group installed inside the unit,easy to remove,convenient to check the spray pump system inside.

LKM Series Counter Flow Closed Cooling Tower

5.High efficiency inlet grille and dual channel design

Use corrosion resistance PVC inlet grille of cooling tower,The dual channel design can prevent water spillage and reduce the possibility of algae production in the unit.The inlet grille around the sink completely enclosed the sink,preventing sunlight from reaching the unit directly,thus preventing algae growth,reducing water treatment requirements and reducing maintenance cost.

At the same time,this kind of air inlet grill also has the characteristics of low air resistance,the water pressure drop can reduce the energy consumption of ventilation and reduce the running cost of equipment.

LKM Series Counter Flow Closed Cooling Tower


LKM Series Counter Flow Closed Cooling Tower

LKM Series Counter Flow Closed Cooling Tower

LKM Series Counter Flow Closed Cooling Tower

Related Products View More +

Contact
Follow Us

All Rights Reserved | Sitemap Technical Support: